GT-LMR240-FLEX COAXIAL CABLE |
Structure
Dimension & Performance |
Item |
Material |
Diameter |
Inner Conductor |
Tinned Standard Copper |
1.42 mm |
Insulator |
Physical Foam Polyethylene |
3.81 mm |
Outer Conductor |
Aluminum Foil + Tinned
Copper Braid |
4.52 mm |
Jacket |
TPU/TPE |
6.10 mm |
|
Electrical Characteristics
Mechanical and Environmental
Characteristics |
Item |
Specification |
Item |
Specification |
Capacitance |
79.4 pF/m |
Min. Bend |
100 mm |
Impedance |
50
Ω |
Storage Temp. |
-40℃-
+80℃ |
Velocity |
84 % |
Installation Temp. |
-40℃-
+80℃ |
Inner Conductor DC Resistance |
10.50
Ω/km |
Operating Temp. |
-40℃-
+80℃ |
Outer Conductor DC Resistance |
12.76 Ω/km |
VSWR |
≤1.10 (800-1000MHz) |
Shielding Effectiveness |
>90 dB |
|
≤1.15 (1700-2400MHz) |
|
Attenuation and Avg. Power(20℃) |
Frequency (MHz) |
Attenuation (dB/100m) |
Avg. Power (KW) |
30 |
4.40 |
1.30 |
50 |
5.70 |
1.00 |
150 |
9.90 |
0.58 |
220 |
12.00 |
0.58 |
450 |
17.30 |
0.33 |
900 |
24.80 |
0.23 |
1500 |
32.40 |
0.18 |
1800 |
35.60 |
0.16 |
2000 |
37.70 |
0.15 |
2500 |
42.40 |
0.13 |
3000 |
46.50 |
0.12 |
5800 |
66.80 |
0.09 |
|
Product Picture |
|
GT-LMR240-FLEX |